Resultados 1 - 20 de 135
Filtrar
1.
Dent. press endod ; 8(1): 34-40, Apr-Jun. 2018. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: biblio-883679

RESUMO

Objetivo: o objetivo do presente trabalho é discutir a importância da variação do ângulo vertical na radiografía periapical, em algumas situações clínicas especiais. Métodos: foram consultadas algumas fontes com o intuito de analisar a utilidade dessa técnica na Endodontia. Resultados: a variação do ângulo vertical na radiografía periapical pode ser empregada em diversas situações clínicas na Endodontia, tais como: a sobreposição do arco zigomático sobre os ápices dos molares superiores, para visualizar ápices muito finos, em casos de fraturas radiculares transversais, para evitar sobreposições das asas dos grampos do isolamento absoluto sobre os ápices dos dentes, durante o tratamento endodôntico. Também, poder ser útil para a detecção de obstruções cervicais do canal radicular e pinos intrarradiculares curtos, em dentes portadores de coroas metálicas, onde é difícil sua visualização. Conclusões: o uso adequado da variação na angulação vertical pode auxiliar na resolução satisfatória desses casos.


Assuntos
Humanos , Masculino , Feminino , Endodontia , Padrões de Prática Odontológica , Radiografia Dentária/métodos , Radiologia
2.
J Endod ; 44(3): 501-505, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-29254816

RESUMO

INTRODUCTION: The aim of this study was to evaluate some of the physicochemical properties of a new root canal sealer. METHODS: The sealers tested were Sealer Plus compared with AH Plus. For the radiopacity, flow, solubility, and fabrication of test specimens relative to setting times, the American National Standards Institute/American Dental Association No. 57 (2000) and International Organization for Standardization 6876 (2012) specifications were followed. To measure the initial and final setting times, the ASTM C266/2008 standard was used. pH was evaluated in the time intervals of 3, 24, 72, and 168 hours. Statistical tests were applied to the results obtained at a level of significance of 5%. RESULTS: The results demonstrated that the Sealer Plus sealer showed a lower radiopacity value than AH Plus sealer (P < .05); however, this was higher than the minimum value recommended by the specifications (ie, 3 mm Al). Relative to flow, the value for Sealer Plus was 19.19 mm and for AH Plus, 19.81 mm (P > .05). Sealer Plus presented initial and final setting times of 138 minutes and 210 minutes, respectively, whereas the values for AH Plus were 437 minutes and 849 minutes, respectively (P < .05). Relative to solubility, Sealer Plus presented 0.21% and AH Plus, 0.27% (P > .05). None of the sealers showed a significant increase in pH (P > .05). CONCLUSIONS: Sealer Plus sealer presented physicochemical properties in accordance with American National Standards Institute/American Dental Association (2000) No. 57 and International Organization for Standardization 6876 (2012) specifications.


Assuntos
Hidróxido de Cálcio/química , Resinas Epóxi/química , Materiais Restauradores do Canal Radicular/química , Fenômenos Químicos , Teste de Materiais
3.
Rev. Salusvita (Online) ; 35(1): 119-127, 2016.
Artigo em Português | LILACS | ID: lil-788585

RESUMO

Introdução: todo canal radicular instrumentado, seja por métodos manuais ou rotatórios, apresentará a formação de uma lama de detritos sobre a parede dentinária, sendo esta composta tanto por matéria orgânica quanto inorgânica, denominada de smear layer. Em relação a sua remoção ou manutenção das paredes do canal, diversos autores apresentaram opiniões e resultados divergentes, gerando dúvidas aos clínicos em relação à conduta mais adequada a ser empregada no tratamento endodôntico. Objetivo: este trabalho, por meio de uma revisão de literatura, visa fornecer uma resposta clara, capaz de melhorar o prognóstico do tratamento. Metodologia: para isso, foram utilizados 25 trabalhos desde o ano de 1975 a 2014, coletados por meio das bases de dados PubMed e Web of Science, com as palavras chaves: "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" e "smear layer sealing". Conclusão: baseado na metodologia proposta pode-se concluir que a remoção da smear layer é a melhor conduta a ser tomada durante o tratamento endodôntico, pois proporciona uma ação antimicrobiana mais eficiente das substâncias irrigadoras e medicações intracanais, além de permitir um melhor selamento entre dentina e material obturador, reduzindo as chances de uma infiltração.


Introduction: the root canal instrumentation, either by manual or mechanicals methods, will result in a formation of debris layer on dentin surface composted by organic and inorganic tissues, denominated smear layer. Due to the several divergent opinion about its removal or maintenance into the root canal, the clinicians may have a doubt for the most appropriate conduct to be performed in endodontics treatments. Objective: this article aimed collect the mains results obtained by different authors to provide a clear answer capable of improving the treatment prognosis. Methods: for this, were used 25 articles since 1975 to 2014 collected by date base PubMed and Web of Science with the keywords "smear layer", "smear layer removal", "smear layer permeability", "smear layer bacteria" and "smear layer sealing". Conclusion: based in the informations obtained in this review, its was concluded that the smear layer removal can, not only, improve the antimicrobial action of the irrigants agents and intracanal medicaments, but also provide a most efficient sealing of the fillingmaterial to dentine wall, reducing the chances to occur a leak in its interface.


Assuntos
Humanos , Masculino , Feminino , Camada de Esfregaço , Permeabilidade da Dentina , Prognóstico , Endodontia
4.
Dent. press endod ; 5(3): 21-27, Sept.-Dec. 2015. ilus
Artigo em Português | LILACS | ID: lil-786288

RESUMO

Introdução: o objetivo deste trabalho foi avaliar, por meio da microscopia confocal de varredura a laser (MCVL), o efeito da medicação intracanal com pasta de hidróxido de cálcio sobre a penetração e a porcentagem de adaptação — nos terços cervical, médio e apical — de canais obturados com o sistema obturador à base de metacrilato (Sistema Epiphany). Métodos: trinta incisivos inferiores humanos foram instrumentados até a lima 40.04 do sistema ProFile e a solução irrigadora usada foi o hipoclorito de sódio. Os dentes foram aleatoriamente divididos em três grupos (n = 10): Grupo I = sem hidróxido de cálcio (Ca(OH)2) (grupo controle); Grupo II = com Ca(OH)2 por 14 dias e remoção com solução salina + lima K #40; e Grupo III = similar ao Grupo II, mas utilizando o EDTA a 17% para remoção da medicação. O cimento Epiphany foi corado com rodamina B, e todos os canais foram obturados com o sistema Epiphany. Três secções de cada dente foram avaliadas sob magnificações de cinco e de quarenta vezes. Resultados: os testes estatísticos de ANOVA e Tukey indicaram significância estatística na redução dos valores de penetração do cimento no terço apical, comparado aos outros terços (p < 0,05). A maior profundidade de penetração foi observada nos terços coronal e médio do Grupo II. Os Grupos II (93%) e III (86%) tiveram as maiores porcentagens de adaptação, comparados ao Grupo I (78%) (p < 0,05). Conclusões: o Ca(OH)2 favoreceu a profundidade de penetração do cimento e a porcentagem de adaptação na interface dentina/cimento em dentes obturados com o cimento à base de metacrilato.


Assuntos
Hidróxido de Cálcio , Corantes Fluorescentes , Microscopia Confocal , Obturação do Canal Radicular
5.
J. appl. oral sci ; 23(6): 591-598, Nov.-Dec. 2015. graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-769816

RESUMO

Objectives To compare three methods of intratubular contamination that simulate endodontic infections using confocal laser scanning microscopy (CLSM). Material and Methods Two pre-existing models of dentinal contamination were used to induce intratubular infection (groups A and B). These methods were modified in an attempt to improve the model (group C). Among the modifications it may be included: specimen contamination for five days, ultrasonic bath with BHI broth after specimen sterilization, use of E. faecalisduring the exponential growth phase, greater concentration of inoculum, and two cycles of centrifugation on alternate days with changes of culture media. All specimens were longitudinally sectioned and stained with of LIVE/DEAD® for 20 min. Specimens were assessed using CLSM, which provided images of the depth of viable bacterial proliferation inside the dentinal tubules. Additionally, three examiners used scores to classify the CLSM images according to the following parameters: homogeneity, density, and depth of the bacterial contamination inside the dentinal tubules. Kruskal-Wallis and Dunn’s tests were used to evaluate the live and dead cells rates, and the scores obtained. Results The contamination scores revealed higher contamination levels in group C when compared with groups A and B (p<0.05). No differences were observed between group A and B (p>0.05). The volume of live cells in group C was higher than in groups A and B (p<0.05). Conclusion The new protocol for intratubular infection resulted in high and uniform patterns of bacterial contamination and higher cell viability in all specimens when compared with the current methods.


Assuntos
Animais , Bovinos , Cavidade Pulpar/microbiologia , Dentina/microbiologia , Modelos Animais de Doenças , Enterococcus faecalis , Centrifugação , Meios de Cultura , Dentina/ultraestrutura , Infecções por Bactérias Gram-Positivas/microbiologia , Viabilidade Microbiana , Microscopia Confocal , Reprodutibilidade dos Testes , Fatores de Tempo
6.
J Appl Oral Sci ; 23(6): 591-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26200524

RESUMO

OBJECTIVES: To compare three methods of intratubular contamination that simulate endodontic infections using confocal laser scanning microscopy (CLSM). MATERIAL AND METHODS: Two pre-existing models of dentinal contamination were used to induce intratubular infection (groups A and B). These methods were modified in an attempt to improve the model (group C). Among the modifications it may be included: specimen contamination for five days, ultrasonic bath with BHI broth after specimen sterilization, use of E. faecalisduring the exponential growth phase, greater concentration of inoculum, and two cycles of centrifugation on alternate days with changes of culture media. All specimens were longitudinally sectioned and stained with of LIVE/DEAD for 20 min. Specimens were assessed using CLSM, which provided images of the depth of viable bacterial proliferation inside the dentinal tubules. Additionally, three examiners used scores to classify the CLSM images according to the following parameters: homogeneity, density, and depth of the bacterial contamination inside the dentinal tubules. Kruskal-Wallis and Dunn's tests were used to evaluate the live and dead cells rates, and the scores obtained. RESULTS: The contamination scores revealed higher contamination levels in group C when compared with groups A and B (p<0.05). No differences were observed between group A and B (p>0.05). The volume of live cells in group C was higher than in groups A and B (p<0.05). CONCLUSION: The new protocol for intratubular infection resulted in high and uniform patterns of bacterial contamination and higher cell viability in all specimens when compared with the current methods.


Assuntos
Cavidade Pulpar/microbiologia , Dentina/microbiologia , Modelos Animais de Doenças , Enterococcus faecalis , Animais , Bovinos , Centrifugação , Meios de Cultura , Dentina/ultraestrutura , Infecções por Bactérias Gram-Positivas/microbiologia , Viabilidade Microbiana , Microscopia Confocal , Reprodutibilidade dos Testes , Fatores de Tempo
7.
Dent. press endod ; 5(1): 19-29, jan.-abr. 2015. ilus, tab
Artigo em Português | LILACS | ID: lil-764825

RESUMO

Objetivo: verificar a ação antimicrobiana, solubilidade, tempo de presa, escoamento, pH, liberação de cálcio e característica da superfície do MTA associado as substancias hipoclorito de sodio gel a 1%, clorexidina gel a 2%, água destilada associada a 10% de propilenoglicol (CCPG), K-Y gel, solução salina e, por fim, água destilada. Métodos: para o teste antimicrobiano, utilizou-se o Streptococcus mutans, Lactobacillus casei, Enterococcus faecalis e Candida albicans, por meio do método de contato direto. Para avaliação do tempo de presa e escoamento, foram utilizadas as especificações ASTM 266/08 e ADA 57/2007. Para o pH e liberação de cálcio, os materiais foram inseridos em cavidades retrogradas de dentes de resina acrílica e imersos em água ultrapura, para avaliação em diferentes períodos, utilizando um pHmetro e um espectrofotômetro de absorção atômica. Para a analise das características de superfície, os dentes de acrílico foram analisados com microscopia eletrônica de varredura (MEV). Resultados: os resultados dos testes antimicrobianos mostraram que os diferentes aditivos associados ao MTA apresentaram maior propriedade inibitória do que bactericida, sendo que a clorexidina apresentou os melhores resultados. As amostras que utilizaram o K-Y gel como veiculo apresentaram maiores índices de solubilidade. Houve diferença estatística entre os grupos (p > 0,05) quanto ao escoamento. O grupo que utilizou o CCPG apresentou o menor tempo de presa. O grupo K-Y apresentou os menores pH e liberação de cálcio no período de três horas. Nos outros períodos, houve maior uniformidade entre os grupos. Com relação as características da superfície, o grupo CCPG apresentou a maior porosidade (p < 0,05). Conclusão: o único veiculo avaliado que proporcionou alguma melhora no efeito antimicrobiano foi a clorexidina gel a 2%. Ja o K-Y gel interferiu nas propriedades físico-químicas do MTA, e a adição de CCPG proporcionou a maior porosidade.


Assuntos
Cálcio , Cimentos Dentários , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão , Fenômenos Químicos , Solubilidade
8.
J. appl. oral sci ; 23(1): 42-48, Jan-Feb/2015. tab, graf
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-741586

RESUMO

Objective: To evaluate the response of rat subcutaneous tissue in implanted polyethylene tubes that were filled with GMTA Angelus and Portland cements containing different arsenic concentrations. Material and Methods: Atomic absorption spectrophotometry was utilized to obtain the values of the arsenic concentration in the materials. Thirty-six rats were divided into 3 groups of 12 animals for each experimental period. Each animal received two implants of polyethylene tubes filled with different test cements and the lateral of the tubes was used as a control group. After 15, 30 and 60 days of implantation, the animals were killed and the specimens were prepared for descriptive and morphometric analysis considering: inflammatory cells, collagen fibers, fibroblasts, blood vessels and other components. The results were analyzed utilizing the Kuskal-Wallis test and the Dunn's Multiple test for comparison (p<0.05). Results: The materials showed, according to atomic absorption spectrophotometry, the following doses of arsenic: GMTA Angelus: 5.01 mg/kg, WPC Irajazinho: 0.69 mg/kg, GPC Minetti: 18.46 mg/kg and GPC Votoran: 10.76 mg/kg. In a 60-day periods, all specimens displayed a neoformation of connective tissue with a structure of fibrocellular aspect (capsule). Control groups and MTA Angelus produced the lower amount of inflammatory reaction and GPC Minetti, the highest reaction. Conclusions: There was no direct relationship between the concentration of arsenic present in the composition of the materials and the intensity of the inflammatory reactions. Higher values, as 18.46 mg/kg of arsenic in the cement, produce characteristics of severe inflammation reaction at the 60-day period. The best results were found in MTA angelus. .


Assuntos
Animais , Masculino , Arsênio/toxicidade , Bismuto/toxicidade , Compostos de Cálcio/toxicidade , Cimentos Dentários/toxicidade , Óxidos/toxicidade , Silicatos/toxicidade , Tela Subcutânea/efeitos dos fármacos , Arsênio/administração & dosagem , Bismuto/química , Vasos Sanguíneos/efeitos dos fármacos , Colágeno/efeitos dos fármacos , Cimentos Dentários/química , Fibroblastos/efeitos dos fármacos , Teste de Materiais , Óxidos/química , Polietileno/química , Ratos Wistar , Valores de Referência , Espectrofotometria Atômica , Fatores de Tempo
9.
J Appl Oral Sci ; 23(1): 42-8, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25075671

RESUMO

OBJECTIVE: To evaluate the response of rat subcutaneous tissue in implanted polyethylene tubes that were filled with GMTA Angelus and Portland cements containing different arsenic concentrations. MATERIAL AND METHODS: Atomic absorption spectrophotometry was utilized to obtain the values of the arsenic concentration in the materials. Thirty-six rats were divided into 3 groups of 12 animals for each experimental period. Each animal received two implants of polyethylene tubes filled with different test cements and the lateral of the tubes was used as a control group. After 15, 30 and 60 days of implantation, the animals were killed and the specimens were prepared for descriptive and morphometric analysis considering: inflammatory cells, collagen fibers, fibroblasts, blood vessels and other components. The results were analyzed utilizing the Kuskal-Wallis test and the Dunn's Multiple test for comparison (p<0.05). RESULTS: The materials showed, according to atomic absorption spectrophotometry, the following doses of arsenic: GMTA Angelus: 5.01 mg/kg, WPC Irajazinho: 0.69 mg/kg, GPC Minetti: 18.46 mg/kg and GPC Votoran: 10.76 mg/kg. In a 60-day periods, all specimens displayed a neoformation of connective tissue with a structure of fibrocellular aspect (capsule). Control groups and MTA Angelus produced the lower amount of inflammatory reaction and GPC Minetti, the highest reaction. CONCLUSIONS: There was no direct relationship between the concentration of arsenic present in the composition of the materials and the intensity of the inflammatory reactions. Higher values, as 18.46 mg/kg of arsenic in the cement, produce characteristics of severe inflammation reaction at the 60-day period. The best results were found in MTA angelus.


Assuntos
Arsênio/toxicidade , Bismuto/toxicidade , Compostos de Cálcio/toxicidade , Cimentos Dentários/toxicidade , Óxidos/toxicidade , Silicatos/toxicidade , Tela Subcutânea/efeitos dos fármacos , Animais , Arsênio/administração & dosagem , Bismuto/química , Vasos Sanguíneos/efeitos dos fármacos , Colágeno/efeitos dos fármacos , Cimentos Dentários/química , Fibroblastos/efeitos dos fármacos , Masculino , Teste de Materiais , Óxidos/química , Polietileno/química , Ratos Wistar , Valores de Referência , Espectrofotometria Atômica , Fatores de Tempo
10.
Rev. Salusvita (Online) ; 34(2)2015. ilus, tab
Artigo em Português | LILACS | ID: lil-775832

RESUMO

Frente aos efeitos deletérios da reabsorção cervical externa, é de grande importância a confecção do tampão cervical quando do clareamento de dentes despolpados. Objetivo: este estudo avaliou a influência do perborato de sódio (PS) e o número de aplicações na desadaptação marginal do tampão cervical. Metodologia: Vinte e quatro pré-molares inferiores foram divididos em três grupos (n=8), de acordo com o material utilizado na confecção do tampão: Cimento de Ionômero de Vidro (CIV), Bioplic (BP) e Agregado de Trióxido Mineral branco (MTA B). Após a aplicação dos materiais, os espécimes foram aplainados e registrados por uma câmera fotográfica acoplada ao Esteromicroscópio. O PS diluído em soro fisiológico foi acomodado sobre os tampões e em seguida selados por 15 dias. Em seguida, o PS foi removido e novas imagens realizadas no Estereomicroscópio. Este ciclo foi repetido, determinando três períodos de avaliação. A desadaptação marginal foi calculada por meio do Software Image J, e os dados submetidos ao teste estatístico de Kruskal-wallis com post-hoc de Dunn para comparação intergrupos (α menor ou igual a 0,05), e teste de Friedman para comparação intragrupos (α menor ou igual a 0,05). Resultados: Verificou-se um aumento significativo na desadaptação marginal do BP e CIV entre os períodos controle e 2ª sessão. Na comparação intergrupos, o MTA B apresentou maior desadaptação quando comparado ao BP em todos os períodos. Conclusão: o PS foi capaz de aumentar a desadaptação marginal de dois materiais após 30 dias, e o MTA B seria o material menos indicado para confecção do tampão cervical...


Due to the deleterious effects of the external cervical resorption, it is extremely important the use of an appropriate cervical barrier in non-vital bleaching. Objective: this study evaluated the influence of sodium perborate (SP) and the number of its application on cervical barrier marginal misfit. Methods: twenty- four human premolars were divided into 3 groups (n=8) according to the material used in manufacture of barrier: Glass Ionomer cement (GIC), Bioplic (BP) and white Mineral Trioxide aggregate (W MTA). After the application of the materials, specimens were planed and registered with a camera mounted in a stereomicroscope. SP diluted in saline was accommodated on the barrier and then sealed for 15 days. Afterwards SP was removed and images were again obtained with stereomicroscope. This cycle was repeated once more, determine three periods of evaluation. Marginal misfit was obtained through Image J software, and the data was subjected to two-way analysis of variance, followed by Tukey post-hoc test (α or less 0,05). Results: there was a significant increase in the marginal misfit of BP and CIV between periods control and 2nd session. In the intergroup comparison, the MTA B showed larger marginal misfit when compared to BP in all periods. Conclusion: the PS was able to increase marginal misfit of 2 materials after 30 days, and the MTA B would be less suitable for making the cervical barrier...


Assuntos
Humanos , Masculino , Feminino , Clareadores Dentários/administração & dosagem , Clareamento Dental/métodos , Peróxido de Hidrogênio/efeitos adversos , Reabsorção da Raiz
11.
Artigo em Português | LILACS | ID: lil-775842

RESUMO

Entende-se que o selamento coronário é tão importante para o sucesso da terapia endodôntica quanto o próprio tratamento em si, podendo ser considerado parte integral deste. Objetivo: realizar uma revisão de literatura sobre os principais seladores coronários temporários e suas propriedades, para elucidar aos endodontistas e clínicos gerais, qual as melhores opções. Resultados e Discussão: a melhor capacidade de vedamento foi atribuída a materiais fotoativados, cimento de ionômero de vidro e coltosol. Porém, a variação de metodologias encontrados na literatura é grande, tornando difícil suas comparações. Conclusões: existe a necessidade de padronização destes testes, e verificação de sua legitimidade para que possamos ter conclusões concretas sobre o assunto em questão...


It is known that the coronal sealing ability is so important to the endodontic therapy`s success, as the treatment itself, could being considered an integral part of it. Objective: a literature review of the main temporary filling materials and their properties, for the avoidance of the incorrect use of these, by endodontics and general practitioners. Results and Discussion: photoactive material, Ionomer Cement Glass and Coltosol were found to exhibit the best coronal seal. However, variation of regimens used in literature was large, making comparison of reports difficult. Conclusion: it is necessary the standardization of these tests and checking of its legitimacy, so we will have concrete conclusions on the subject in question...


Assuntos
Humanos , Masculino , Feminino , Endodontia , Materiais Dentários/análise , Restauração Dentária Temporária
12.
Microsc Res Tech ; 77(12): 1031-6, 2014 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-25209870

RESUMO

This study analyzed the quality of obturation and physical properties of MTA Fillapex and AH Plus sealer. A sample of 30 human maxillary central incisors were instrumented with Protaper until a F5 (50/05) file. Both sealers were mixed with Rhodamine-B dye to allow visualization on a confocal laser-scanning microscope (CLSM). Next, the canals were filled using the single cone technique. After setting, all samples were sectioned at 2, 4, and 6 mm from the apex. CLSM was used to analyze the gaps and sealer penetration into the dentinal tubules. All samples were scanned 10 µm below the dentin surface and images were recorded at 100× magnification using the fluorescent mode. Additionally, the solubility, flowability and setting time of the sealers were evaluated. All the measured quantities of the examined materials were evaluated for significant differences by means of statistical analysis. The CLSM analysis of the MTA Fillapex showed the highest percentage of gaps at all sections (P = 0.0001). Physical tests revealed adequate properties for both sealers except for a higher solubility of the MTA Fillapex (P = 0.0001). The MTA Fillapex presented flowability and intratubular penetration similar to the AH Plus. Nevertheless, the MTA Fillapex sealer presented a higher solubility and considerable quantity of gaps between the sealer/dentin interface in relation to the AH Plus sealer. Clinicians must take into consideration, the quality of endodontic sealers as it is essential in the outcome of the root canal filling.


Assuntos
Incisivo/ultraestrutura , Microscopia Confocal , Materiais Restauradores do Canal Radicular/química , Obturação do Canal Radicular/métodos , Dentina/ultraestrutura , Humanos , Solubilidade , Propriedades de Superfície
13.
Braz Oral Res ; 282014.
Artigo em Inglês | MEDLINE | ID: mdl-25166765

RESUMO

This study compared the fluid filtration, adaptation to the root canal walls, and the push-out bond strength of two resin-based sealers and three calcium silicate-based retrograde filling materials. Fifty maxillary canines were shaped using manual instruments and the apical portion was sectioned. Retrograde cavities of 3-mm depth were prepared. The specimens were divided into five groups (n = 10): Sealer 26 (S26); MBPc (experimental); MTA; Portland cement with 20% zirconium oxide (PC/ZO), and Portland cement with 20% calcium tungstate (PC/CT). The fluid filtration was measured at 7 and 15 days. To evaluate the interfacial adaptation, sections of the teeth, 1 and 2 mm from the apex, were prepared and the percentage of gaps was calculated. The push-out bond strength at 2 mm from the apex was evaluated. Statistical analysis was performed using the ANOVA/Tukey's test (p < 0.05). At 7 and 15 days (p = 0.0048, p = 0.006), the PC/CT group showed higher fluid filtration values when compared to other groups. At 1 mm from the apex, no statistical differences in the adaptation were found among the cements (p = 0.44). At 2 mm from the apex, the PC/ZO group presented statistically lower percentage of gaps than S26, MBPc, and MTA (p = 0.0007). The MBPc group showed higher push-out bond strength than other cements evaluated (p = 0.0008). The fluid filtration and interfacial adaptation of the calcium silicate-based cements were similar to those of the resin-based cements. The resinous cement MBPc showed superior push-out bond strength.


Assuntos
Colagem Dentária/métodos , Adaptação Marginal Dentária , Obturação Retrógrada/métodos , Materiais Restauradores do Canal Radicular/química , Compostos de Alumínio/química , Análise de Variância , Bismuto/química , Compostos de Cálcio/química , Hidróxido de Cálcio/química , Infiltração Dentária/prevenção & controle , Combinação de Medicamentos , Humanos , Teste de Materiais , Óxidos/química , Reprodutibilidade dos Testes , Cimentos de Resina/química , Obturação Retrógrada/instrumentação , Silicatos/química , Fatores de Tempo , Compostos de Tungstênio/química , Zircônio/química
14.
J Appl Oral Sci ; 21(1): 32-6, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-23559109

RESUMO

OBJECTIVE: To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. MATERIAL AND METHODS: Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. RESULTS: Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). CONCLUSIONS: All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinker.


Assuntos
Compostos de Alumínio/química , Materiais Biocompatíveis/química , Compostos de Cálcio/química , Sulfato de Cálcio/química , Cimentos Dentários/química , Óxidos/química , Silicatos/química , Tela Subcutânea , Animais , Combinação de Medicamentos , Masculino , Teste de Materiais , Ratos , Ratos Wistar , Propriedades de Superfície , Fatores de Tempo
15.
Full dent. sci ; 4(14): 346-351, jan.-mar. 2013. ilus
Artigo em Português | LILACS, BBO - Odontologia | ID: lil-681712

RESUMO

Analisou-se microscopicamente o processo de reparo de incisões realizadas na derme de ratos, utilizando três pontas diferentes do laser de Erbio YAG. Foram selecionados 6 ratos, nos quais, após depilação da região dorsal e anestesia, foram submetidos a incisões com o Laser Erbio-YAG, utilizando as peças de mão 2051, peça de mão 2055 com fibra óptica de forma cilíndrica e peça de mão 2056 com fibra óptica de forma de espátula. Os animais foram mortos após 7 e 14 dias, sendo que nesse momento, as feridas incisionais foram fotografadas. As peças contendo a região incisada foram preparadas para análise microscópica, realizando-se secções de 7µm e coloração com hematoxilina e eosina. Avaliou-se a zona de ablação tecidual, zona de necrose térmica, presença e característica das células inflamatórias e o processo de reparo. A peça de mão 2051 foi a que propiciou corte mais rápido e produziu bordas de ferida mais definidas. Para realizar uma incisão de 1.30 mm de profundidade foi necessário passar as peças de mão do laser cinco vezes no mesmo local. Não houve diferença no processo de reparo nas incisões realizadas com os três tipos de peças de mão do laser de Erbio Yag


The study analised microscopic wound healing of incision made with Er:YAg laser with three different tips. In six Rattus norvegicus, incision was made with Laser Er-YAG (KeyLaser) using tips 2051, 2055 and 2056. The animals were killed at 7 e 14 and the sites of incision are photographed in this time. The parts containing the incision area were prepared for microscopic analysis, performing sections of 7µm and staining with haematoxylin and eosin. Zone of tissue ablation, zone of thermal necrosis, the presence and character of inflammatory cell infiltrate and wound healing were measured. The 2051 tip produced faster and defined edges of the wound. To create wound 1.30 mm in depth lasers tips required at last five passes within the same line of incision. Microscopic analysis shows no difference with use of three different laser tips


Assuntos
Animais , Ratos , Endodontia/métodos , Lasers , Microscopia , Suturas
16.
J. appl. oral sci ; 21(1): 32-36, 2013. ilus, tab
Artigo em Inglês | LILACS, BBO - Odontologia | ID: lil-684992

RESUMO

Objective: To evaluate the biocompatibility and the setting time of Portland cement clinker with or without 2% or 5% calcium sulfate and MTA-CPM. Material and Methods: Twenty-four mice (Rattus norvegicus) received subcutaneously polyethylene tubes filled with Portland cement clinker with or without 2% or 5% calcium sulfate and MTA. After 15, 30 and 60 days of implantation, the animals were killed and specimens were prepared for microscopic analysis. For evaluation of the setting time, each material was analyzed using Gilmore needles weighing 113.5 g and 456.5 g, according to the ASTM specification Number C266-08 guideline. Data were analyzed by ANOVA and Tukey's test for setting time and Kruskal-Wallis and Dunn test for biocompatibility at 5% significance level. Results: Histologic observation showed no statistically significant difference of biocompatibility (p>0.05) among the materials in the subcutaneous tissues. For the setting time, clinker without calcium sulfate showed the shortest initial and final setting times (6.18 s/21.48 s), followed by clinker with 2% calcium sulfate (9.22 s/25.33 s), clinker with 5% calcium sulfate (10.06 s/42.46 s) and MTA (15.01 s/42.46 s). Conclusions: All the tested materials showed biocompatibility and the calcium sulfate absence shortened the initial and final setting times of the white Portland cement clinker.


Assuntos
Animais , Masculino , Ratos , Compostos de Alumínio/química , Materiais Biocompatíveis/química , Compostos de Cálcio/química , Sulfato de Cálcio/química , Cimentos Dentários/química , Óxidos/química , Tela Subcutânea , Silicatos/química , Combinação de Medicamentos , Teste de Materiais , Ratos Wistar , Propriedades de Superfície , Fatores de Tempo
17.
J Appl Oral Sci ; 20(5): 522-5, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23138737

RESUMO

OBJECTIVES: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. MATERIAL AND METHODS: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. RESULTS: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). CONCLUSIONS: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.


Assuntos
Instrumentos Odontológicos , Cavidade Pulpar/diagnóstico por imagem , Odontometria , Radiografia Dentária Digital/métodos , Preparo de Canal Radicular , Ápice Dentário/diagnóstico por imagem , Cavidade Pulpar/anatomia & histologia , Eletrônica Médica/instrumentação , Humanos , Odontometria/instrumentação , Tamanho do Órgão , Reprodutibilidade dos Testes , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Ápice Dentário/anatomia & histologia
18.
J Appl Oral Sci ; 20(4): 404-9, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-23032200

RESUMO

OBJECTIVE: This study compared the influence of three epoxy resin-based sealers with distinct radiopacities on the observers' ability to detect root canal filling voids during radiographic analysis. MATERIAL AND METHODS: The root canals of 48 extracted maxillary canines were prepared and divided into three groups. Each group was laterally condensed with one sealer (AH Plus®, Acroseal® or a non-radiopaque sealer), and a longitudinal void was simulated in half of the specimens from each group (n=8). Buccolingual radiographs were obtained and randomly interpreted for voids by a radiologist and an endodontist in a blinded fashion. Teeth were cut and inspected under a microscope to confirm the position of void. Differences in sensitivity and specificity between groups and examiners were compared using the Fisher's Exact and McNemar tests, respectively (α=0.05). RESULTS: Significantly lower sensitivity levels (p<0.05) were observed in the coronal portion of fillings performed with both radiopaque sealers. Specificity values for Acroseal® were significantly higher (p<0.05) in the coronal and apical portions of fillings. CONCLUSIONS: The type of root canal sealer can affect the observers' ability to detect root canal filling voids during radiographic analysis of upper single-rooted teeth.


Assuntos
Cavidade Pulpar/diagnóstico por imagem , Resinas Epóxi/química , Materiais Restauradores do Canal Radicular/química , Raiz Dentária/diagnóstico por imagem , Animais , Cães , Teste de Materiais , Maxila , Variações Dependentes do Observador , Radiografia Dentária/normas , Distribuição Aleatória , Sensibilidade e Especificidade
19.
J. appl. oral sci ; 20(5): 522-525, Sept.-Oct. 2012. ilus
Artigo em Inglês | LILACS | ID: lil-654915

RESUMO

OBJECTIVES: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. MATERIAL AND METHODS: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. RESULTS: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). CONCLUSIONS: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.


Assuntos
Humanos , Instrumentos Odontológicos , Cavidade Pulpar , Odontometria , Preparo de Canal Radicular , Radiografia Dentária Digital/métodos , Ápice Dentário , Cavidade Pulpar/anatomia & histologia , Eletrônica Médica/instrumentação , Tamanho do Órgão , Odontometria/instrumentação , Reprodutibilidade dos Testes , Preparo de Canal Radicular/instrumentação , Preparo de Canal Radicular/métodos , Ápice Dentário/anatomia & histologia
20.
RGO (Porto Alegre) ; 60(3): 305-308, jul.-set. 2012. ilus
Artigo em Inglês | LILACS, BBO - Odontologia | ID: biblio-874690

RESUMO

Objective: Evaluate the accuracy of the Brazilian market of endodontic millimeter rulers. Methods: The endodontic millimeter rulers were divided into four experimental groups of 10 rulers each, according to the commercial brand: Group 1 - Jon (Comércio de Produtos Odontológicos Ltda., São Paulo, Brazil), Group 2 - Microdont (Microusinagem de Precisão Ltda., Socorro, Brazil), Group 3 - Angelus (Angelus Soluções Odontológicas, Londrina, Brazil) e Group 4 - ICE (Instrumentos Cirúrgicos Esmeralda Ltda., São Paulo, Brazil). In each endodontic ruler the measure of 20.00 mm was verified with an electronic digital caliper. The results were statistically tested using variance analysis ANOVA followed by Turkey test with p <0.05. Results: The results showed that the average measures of the rulers are not exact, ranging from 19.80 mm to 20.27 mm for the brand ICE (Instrumentos Cirúrgicos Esmeralda Ltda., São Paulo, Brazil). The brand Angelus (Angelus Soluções Odontológicas, Londrina, Brazil) had the lowest variation and exact measurement in 60% of rulers examined. There was no significant difference between brands.Conclusion: The endodontic millimeter rulers analyzed were not standardized and accurate, so the professional should use the same ruler from the beginning to the end of the treatment.


Objetivo: Avaliar a precisão de réguas endodônticas milimetradas comercializadas no Brasil. Métodos: As réguas endodônticas milimetradas foram divididas em 4 grupos experimentais de 10 réguas cada, de acordo com a marca comercial: Grupo 1 - Jon (Comércio de Produtos Odontológicos Ltda., São Paulo, Brasil), Grupo 2 - Microdont (Microusinagem de Precisão Ltda., Socorro, Brasil), Grupo 3 - Angelus (Angelus Soluções Odontológicas, Londrina, Brasil) e Grupo 4 - ICE (Instrumentos Cirúrgicos Esmeralda Ltda., São Paulo, Brasil). Em cada régua foi aferida a medida de 20,00mm por meio de um paquímetro digital eletrônico. Os resultados obtidos foram submetidos à análise estatística utilizando Análise de Variância ANOVA, seguido do teste de Turkey com p<0,05. Resultados: Os resultados demonstraram que a média das medidas das réguas não são exatas, variando desde 19,80mm até 20,27mm para a marca ICE (Instrumentos Cirúrgicos Esmeralda Ltda., São Paulo, Brasil). A marca Angelus (Angelus Soluções Odontológicas, Londrina, Brasil) apresentou a menor variação e a medida exata em 60% das réguas examinadas. Não houve diferença significante entre as marcas. Conclusão: As réguas endodônticas milimetradas analisadas, não se mostraram padronizadas e precisas, devendo o profissional utilizar a mesma régua do início ao fim do tratamento.


Assuntos
Endodontia , Instrumentos Odontológicos , Odontometria
SELEÇÃO DE REFERÊNCIAS